AX181000 TC/Analog Inputs to CAN Controller

4 TC, 7 Analog, 3 Universal Inputs Controller, 2 SAE J1939 

The TC/Analog Inputs to CAN Controller receives inputs from engine coolant, fuel and differential pressure sensors, engine temperature sensors, thermistors as well as thermocouples and is networked to a SAE J1939 based control system. Seven +5V references (10 mA) are provided to power the sensors. The 2 CAN ports are isolated from signal inputs and thermocouple inputs.

Using the Electronic Assistant® programming tool, the user can select the desired inputs from the following signal options.

  • 4 Thermocouples (Type J, K or T)
  • 7 Analog Signals (0-5 V, 0-10V, 0-20 mA, 4-20 mA)
  • 3 Universal Signal Inputs (0-5V, 0-10V, Thermistor, 0-20 mA, 4-20 mA, PWM, Frequency or Counter, Discrete)

A rugged power supply interface accepts 12 Vdc, 24 Vdc or 48 Vdc nominal for battery powered machine applications. The unit carries an IP67 rating. It carries a CE mark. The rugged enclosure with four 12 pin Deutsch IPD connectors is suitable for diesel engine environments. It operates from -40 to 85°C (-40 to 185°F).

Applications:

  • Power gen set engine control systems
  • Oil and gas equipment automation
  • Marine engine applications
  • Off-highway machine automation