Dual Universal Signal Conditioner, CAN bus
The dual channel universal signal converter accepts two voltage, current, resistive, frequency, RPM, PWM or digital control signal inputs and converts them into two signal outputs (analog voltage, analog current or digital signal). The control can be networked to a SAE J1939 networked engine control system.
The unit has isolation between power and CAN.
Using the Electronic Assistant® programming tool, the user can select the desired inputs from the following signal options.
A +5V, 50 mA reference is available to power a sensor input.
The outputs can also be programmed as 0-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA, Frequency, RPM, PWM or digital on/off signals.
A rugged power supply interface accepts 12 Vdc or 24 Vdc nominal for battery powered machine applications. The unit carries an IP67 rating. The rugged enclosure with 12 pin Deutsch IPD connector is suitable for harsh environments. It operates from -40 to 85°C (-40 to 185°F).
Applications:
Contact form description.