- ENGINE & MACHINERY SOLUTIONS
- TELEMETRY SOLUTIONS
- DEBARKERS
- BRANDS
- POPULAR PARTS
🎄GREETINGS OF THE SEASON. KINDLY NOTE WE’RE TAKING A BREAK FROM 4PM FRIDAY 20/12 UNTIL 9AM MONDAY 6/1/25🎄
🎄GREETINGS OF THE SEASON. KINDLY NOTE WE’RE TAKING A BREAK FROM 4PM FRIDAY 20/12 UNTIL 9AM MONDAY 6/1/25🎄
SDB500-2: Direct Mounting Temperature Swichgage for exhaust gas temperature; 100-500°F. (10701115)
The SDB500 is a Direct Mounting Temperature Swichgage instrument used to monitor gas compressor temperatures or engine exhaust temperatures.
It is an accurate direct-reading gauge with an adjustable limit switch to activate alarms and/or shutdown.
A knob on the front of the instrument allows you to adjust the limit switch trip point.
Pointer movement is actuated by a bi-metallic sensing element. When the indicating pointer on the SDB500 touches the adjustable contact, a one-wire-to-ground circuit is completed to shut down the equipment and/or actuate audible or visible alarms.
Proper relays or Tattletale annunciators (magnetic switches) must be incorporated into the system.
The SDB500 has a sand-cast aluminium case with a high-torque bi-metal sensing element in heliarc welded stainless steel bulb.
This dual-scale instrument has a temperature range of 100-500°F (40-260°C), with a maximum unit temperature of 625°F (329°C). Use of a thermowell is recommended. Murphy offers thermowells (separable sockets) to facilitate maintenance of a temperature Swichgage and to protect the temperature sensing bulb from extreme amounts of system pressure. Two thermowell options are available: 1/2 NPT and 3/4 NPT.
Contact form description.
Collections: SDB Series Temperature Swichgage